901 resultados para high sensitivity troponin


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: Concentrations of troponin measured with high sensitivity troponin assays are raised in a number of emergency department (ED) patients; however many are not diagnosed with acute myocardial infarction (AMI). Clinical comparisons between the early use (2 h after presentation) of high sensitivity cardiac troponin T (hs-cTnT) and I (hs-cTnI) assays for the diagnosis of AMI have not been reported. Design and methods: Early (0 h and 2 h) hs-cTnT and hs-cTnI assay results in 1571 ED patients with potential acute coronary syndrome (ACS) without ST elevation on electrocardiograph (ECG) were evaluated. The primary outcome was diagnosis of index MI adjudicated by cardiologists using the local cTnI assay results taken ≥6 h after presentation, ECGs and clinical information. Stored samples were later analysed with hs-cTnT and hs-cTnI assays. Results: The ROC analysis for AMI (204 patients; 13.0%) for hs-cTnT and hs-cTnI after 2 h was 0.95 (95% CI: 0.94–0.97) and 0.98 (95% CI: 0.97–0.99) respectively. The sensitivity, specificity, PLR, and NLR of hs-cTnT and hs-cTnI for AMI after 2 h were 94.1% (95% CI: 90.0–96.6) and 95.6% (95% CI: 91.8–97.7), 79.0% (95% CI: 76.8–81.1) and 92.5% (95% CI: 90.9–93.7), 4.48 (95% CI: 4.02–5.00) and 12.86 (95% CI: 10.51–15.31), and 0.07 (95% CI: 0.04–0.13) and 0.05 (95% CI:0.03–0.09) respectively. Conclusions: Exclusion of AMI 2 h after presentation in emergency patients with possible ACS can be achieved using hs-cTnT or hs-cTnI assays. Significant differences in specificity of these assays are relevant and if using the hs-cTnT assay, further clinical assessment in a larger proportion of patients would be required.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims
Our aim was to test the prediction and clinical applicability of high-sensitivity assayed troponin I for incident cardiovascular events in a general middle-aged European population.

Methods and results
High-sensitivity assayed troponin I was measured in the Scottish Heart Health Extended Cohort (n = 15 340) with 2171 cardiovascular events (including acute coronary heart disease and probable ischaemic strokes), 714 coronary deaths (25% of all deaths), 1980 myocardial infarctions, and 797 strokes of all kinds during an average of 20 years follow-up. Detection rate above the limit of detection (LoD) was 74.8% in the overall population and 82.6% in men and 67.0% in women. Troponin I assayed by the high-sensitivity method was associated with future cardiovascular risk after full adjustment such as that individuals in the fourth category had 2.5 times the risk compared with those without detectable troponin I (P < 0.0001). These associations remained significant even for those individuals in whom levels of contemporary-sensitivity troponin I measures were not detectable. Addition of troponin I levels to clinical variables led to significant increases in risk prediction with significant improvement of the c-statistic (P < 0.0001) and net reclassification (P < 0.0001). A threshold of 4.7 pg/mL in women and 7.0 pg/mL in men is suggested to detect individuals at high risk for future cardiovascular events.

Conclusion
Troponin I, measured with a high-sensitivity assay, is an independent predictor of cardiovascular events and might support selection of at risk individuals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

 Objective: To determine whether introduction of high-sensitivity cardiac troponin I (hscTn-I) assays aff ected management of patients presenting with suspected acute coronary syndrome (ACS) to the emergency department (ED) of a tertiary referral hospital. Design, patients and setting: A retrospective analysis of all patients presenting to the Geelong Hospital ED with suspected ACS from 23 April 2010 to 22 April 2013 -2 years before and 1 year after the changeover to hscTn-I assays on 23 April 2012. Main outcome measures: Hospital admission rates, time spent in the ED, rates of coronary angiography, rates of percutaneous coronary intervention (PCI) and coronary artery bypass graft surgery (CABGS), rates of discharge with a diagnosis of ACS, and rates of inhospital mortality. Results: 12 360 consecutive patients presented with suspected ACS during the study period; 1897 were admitted to Geelong Hospital in the 2 years before and 944 in the 1 year after the changeover to hscTn-I assays. Comparing the two patient groups, there was no statistically signifi cant diff erence in allhospital admission rates (95% CI for the diff erence, - 3.1% to 0.3%; P = 0.10) or proportion of patients subsequently discharged with a diagnosis of ACS (95% CI for the diff erence, - 2.3% to 5.4%; P = 0.43). After the changeover, the median time patients spent in the ED was 11.5% shorter (3.85 h v 4.35 h; 95% CI for the diff erence, - 0.59 to - 0.43; P < 0.001) and the proportion of admitted patients undergoing coronary angiography was higher (53.4% v 45.2%; 95% CI for the diff erence, 4.3 to 12.0 percentage points; P < 0.001), but there was no statistically signifi cant rise in the proportion of patients who had invasive treatment (PCI and/or CABGS) (95% CI for the diff erence, - 0.4% to 6.3%; P = 0.08). Inhospital mortality rates from ACS did not change signifi cantly (95% CI for the diff erence, - 1.5% to 0.8%; P = 0.43). Conclusion: The introduction of hscTn-I assays appeared to be associated with more rapid diagnosis, resulting in less time spent in the ED, without a change in hospital admission rates. A higher proportion of patients had coronary angiographies after the changeover, but there was no signifi cant change in rates of invasive treatment or inhospital mortality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Cardiac troponin detected by new-generation, highly sensitive assays predicts clinical outcomes among patients with stable coronary artery disease (SCAD) treated medically. The prognostic value of baseline high-sensitivity cardiac troponin T (hs-cTnT) elevation in SCAD patients undergoing elective percutaneous coronary interventions is not well established. This study assessed the association of preprocedural levels of hs-cTnT with 1-year clinical outcomes among SCAD patients undergoing percutaneous coronary intervention. METHODS AND RESULTS Between 2010 and 2014, 6974 consecutive patients were prospectively enrolled in the Bern Percutaneous Coronary Interventions Registry. Among patients with SCAD (n=2029), 527 (26%) had elevated preprocedural hs-cTnT above the upper reference limit of 14 ng/L. The primary end point, mortality within 1 year, occurred in 20 patients (1.4%) with normal hs-cTnT versus 39 patients (7.7%) with elevated baseline hs-cTnT (P<0.001). Patients with elevated hs-cTnT had increased risks of all-cause (hazard ratio 5.73; 95% confidence intervals 3.34-9.83; P<0.001) and cardiac mortality (hazard ratio 4.68; 95% confidence interval 2.12-10.31; P<0.001). Preprocedural hs-TnT elevation remained an independent predictor of 1-year mortality after adjustment for relevant risk factors, including age, sex, and renal failure (adjusted hazard ratio 2.08; 95% confidence interval 1.10-3.92; P=0.024). A graded mortality risk was observed across higher tertiles of elevated preprocedural hs-cTnT, but not among patients with hs-cTnT below the upper reference limit. CONCLUSIONS Preprocedural elevation of hs-cTnT is observed in one fourth of SCAD patients undergoing elective percutaneous coronary intervention. Increased levels of preprocedural hs-cTnT are proportionally related to the risk of death and emerged as independent predictors of all-cause mortality within 1 year. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT02241291.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present study, we wanted to (1) evaluate whether high-sensitive troponin T levels correlate with the grade of renal insufficiency and (2) test the accuracy of high-sensitive troponin T determination in patients with renal insufficiency for diagnosis of acute myocardial infarction (AMI). In this cross-sectional analysis, all patients who received serial measurements of high-sensitive troponin T from August 1, 2010, to October 31, 2012, at the Department of Emergency Medicine were included. We analyzed data on baseline characteristics, reason for referral, medication, cardiovascular risk factors, and outcome in terms of presence of AMI along with laboratory data (high-sensitive troponin T, creatinine). A total of 1,514 patients (67% male, aged 65 ± 16 years) were included, of which 382 patients (25%) had moderate to severe renal insufficiency and significantly higher levels of high-sensitive troponin T on admission (0.028 vs 0.009, p <0.0001). In patients without AMI, high-sensitive troponin T correlated inversely with the estimated glomerular filtration rate (R = -0.12, p <0.0001). Overall, sensitivity of an elevated high-sensitive troponin for diagnosis of AMI was 0.64 (0.56 to 0.71) and the specificity was 0.48 (0.45 to 0.51). The area under the curve of the receiver operating characteristic for all patients was 0.613 (standard error [SE] 0.023), whereas it was 0.741 (SE 0.029) for patients with a Modification of Diet in Renal Disease estimated glomerular filtration rate >60 ml/min presenting with acute chest pain or dyspnea and 0.535 (SE 0.056) for patients with moderate to severe renal insufficiency presenting with acute chest pain or dyspnea. In conclusion, the diagnostic accuracy for presence of AMI of a baseline measurement of high-sensitive troponin in patients with renal insufficiency was poor and resembles tossing a coin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a plasmonic “ac Wheatstone bridge” circuit is proposed and theoretically modeled for the first time. The bridge circuit consists of three metallic nanoparticles, shaped as rectangular prisms, with two nanoparticles acting as parallel arms of a resonant circuit and the third bridging nanoparticle acting as an optical antenna providing an output signal. Polarized light excites localized surface plasmon resonances in the two arms of the circuit, which generate an optical signal dependent on the phase-sensitive excitations of surface plasmons in the antenna. The circuit is analyzed using a plasmonic coupling theory and numerical simulations. The analyses show that the plasmonic circuit is sensitive to phase shifts between the arms of the bridge and has the potential to detect the presence of single molecules.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method of making full use of the durable strain which fiber Bragg grating (FBG) can undertake is presented, which hugely improves the sensitivities of FBG temperature sensors at high temperature. When a sensor is manufactured at room temperature, its FBG should be given a pre-relaxing length according to the temperature it is asked to measure; once the temperature rise to the asked one, its FBG starts to be stretched and it starts to work with high sensitivity. The relationship between the pre-relaxing length and the working temperature is analyzed. In experiments, when the pre-relaxing lengths are 0.2mm、0.5mm、0.6mm, the working temperatures rise 25℃、50℃、61℃, respectively, and the sensitivities are almost the same (675pm/℃). The facts that the experimental results agree well with the theoretical analyses verify this method’s validity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

FET based MEMS microphones comprise of a flexible diaphragm that works as the moving gate of the transistor. The integrated electromechanical transducer can be made more sensitive to external sound pressure either by increasing the mechanical or the electrical sensitivities. We propose a method of increasing the overall sensitivity of the microphone by increasing its electrical sensitivity. The proposed microphone uses the transistor biased in the sub-threshold region where the drain current depends exponentially on the difference between the gate-to-source voltage and the threshold voltage. The device is made more sensitive without adding any complexity in the mechanical design of the diaphragm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An experimental setup has been realized to measure weak magnetic moments which can be modulated at radio frequencies (similar to 1-5 MHz). Using an optimized radio-frequency (RF) pickup coil and lock-in amplifier, an experimental sensitivity of 10(-15) Am(2) corresponding to 10(-18) emu has been demonstrated with a 1 s time constant. The detection limit at room temperature is 9.3 x 10(-16) Am(2)/root Hz limited by Johnson noise of the coil. The setup has been used to directly measure the magnetic moment due to a small number (similar to 7 x 10(8)) of spin polarized electrons generated by polarization modulated optical radiation in GaAs and Ge. (C) 2011 American Institute of Physics. [doi: 10.1063/1.3654229]

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The phenomenon of resistive switching (RS) has been demonstrated in several non-magnetic and some magnetic oxide systems, however the ``magnetic'' aspect of magnetic oxides has not been emphasized especially in terms of low field tunability. In our work, we examined the CoFe2O4/La0.66Sr0.34MnO3 all-magnetic oxide interface system for RS and discovered a very sharp (bipolar) transition at room temperature that can be gated with high sensitivity by low magnetic fields (similar to 0-100 mT). By using a number of characterizations, we show that this is an interface effect, which may open up interesting directions for manipulation of the RS phenomenon. (C) 2012 American Institute of Physics. http://dx.doi.org/10.1063/1.4707373]

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, micro gas sensor was fabricated using indium oxide nanowire for effective gas detection and monitoring system. Indium oxide nanowire was grown using thermal CVD, and their structural properties were examined by the SEM, XRD and TEM. The electric properties for microdropped indium oxide nanowire device were measured, and gas response characteristics were examined for CO gas. Sensors showed high sensitivity and stability for CO gas. And with below 20 mw power consumption, 5 ppm CO could be detected.